Contact your localalpine trussmanufacturerorofficeformoreinformation.
Raised tie roof truss spans.
The raised tie roof truss imposes a horizontal load onto the wall plate and wall when loaded.
To achieve maximum indicated spans trusses may require six or more panels.
Typical roof truss design spans.
First off the raised tie roof truss design is an extremely basic direct and utilitarian design every single current trademark.
The truss has an internal web configuration shaped like a w to give the ultimate strength to material ratio for spans from around 5m to around 9m in span which covers the majority of domestic dwelling being built today.
Unlike the conventional truss which is fully triangulated by virtue of its bottom chord fixing the top chords together the raised tie roof completes its triangulation at the flat ceiling to sloping ceiling intersection.
Rafter tie a tension tie in the lower third of opposing gable rafters that is intended to resist the outward thrust of the rafter under load.
While this article focuses on configurations we also have a very cool set of illustrations showcasing the different parts anatomy of roof trusses.
Building code limits the tie to the lower third of the distance between the plate and ridge consult irc table r802 5 1 for rafter span adjustment factors for rafter sizing with raised ties l rafter span w load on rafter l x rafter spacing x roof design load h height of ridge above plate h distance between tie and ridge.
The load span tables shown below demonstrate only a tiny subset of the possible combinations available with trussteel cfs roof trusses.
44 raised tie roof construction up to 5m span rafter size tie joist h max span max 50 x 175 or 38 x 200 50 x 175 575 5000 38 x 175 38 x 175 450 5000 38 x 150 38 x 150 325.
Bt b tc 6 6 common truss configurations for the most widely designed roof shapes.
Roof truss spans every trussteel roof truss is a custom design based upon the unique load span bearing use and code criteria of a particular project.
These trusses are the solution when the internal ceiling height is required to be higher than that of the wall plate.
Mono used where the roof is required to.
The raised tie roof truss design can go up against different style that when nitty gritty right can ooze a cutting edge feel.
A tension tie in the upper third of opposing gable rafters that is intended to resist rafter separation from the ridge because of wind or unbalanced roof loads.
Trusses with an asterisk that exceed 14 in height may be shipped in two pieces.
Main features raised tie roof truss design.
Collar tie is a colloquial term for collar beam.